Filter Results By:

Products

Applications

Manufacturers

Showing results: 2101 - 2115 of 2632 items found.

  • AC/DC Clamp Meter

    3904 CL - Standard Electric Works Co., Ltd

    ● 4000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.

  • Digital Multimeter

    6410 DM - Standard Electric Works Co., Ltd

    ● 3000 counts with a maximum display of 2999.● Angled display design helps the user to identify the reading of value easier.● Auto scanning function for AC/DC voltage, and current.● Auto ranging.● Range change function.● Continuity check.● Diode & Capacitance measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.

  • TRUE RMS AC Clamp Meter

    2960 CL - Standard Electric Works Co., Ltd

    ● True RMS measurement.● Pocket size.● 4000 counts.● Full automatic measurement. Voltage measurement. Current measurement. Resistor measurement.● Data hold function.● Continuity check.● Diode measurement.● Select function.● Low battery indication.● Auto off function.● Flashlight (Auto off in 1 minute).● Re-power on by pushing any of the push buttons or by changing the rotary switch mode after auto power off.

  • Digital Multimeter

    PDMT25 - Pyle Audio Inc.

    4000 Display CountPeak Capture ModeData HoldMax/Min Recording ModeVoltage DC: Max Range 1000 V, Accuracy +/- 0.5%Voltage AC: Max Range 1000 V, Accuracy +/- 0.8%Current DC: Max Range 10 A, Accuracy +/- 1.2%Current AC: Max Range 10 A, Accuracy +/- 1.8%Resitance: Max Range 40 M, Accuracy +/- 0.8%Duty Cycle: Max Range 99.9%, Accuracy +/- 1.2%Temperature: Max Range 760 C / 1400 F, Accuracy +/- 3.0%Frequency: Max Range 10 MHz, Accuracy: +/- 1.5%Capacitance: Max Range 40 mF, Accuracy +/- 1.5%Diode Check

  • Diode Laser Driver

    D200 - Highland Technology, Inc.

    The D200 is a compact, DC-coupled fast laser driver, providing up to 4 amps of regulated constant current. A built-in edge-triggered pulse generator produces up to 1 microsecond pulse widths and 2 nanosecond transition times, capable of driving lasers with forward voltages up to 9 volts. A pulse-follower mode is also provided, accommodating externally-defined trigger widths up to 100% duty continuous-wave (CW). Power, pulse width, drive current and differential triggering functions are accessible through a ribbon cable header for embedded OEM applications. A low-inductance laser drive interface permits direct laser connection or custom interposer and flex-cable attachment.

  • Programmable Setpoint Relay Protection Relay, Trip Relay

    CRD-005 and CRD-020 - Powertek LLC

    CRD-020 Programmable ac current set-point relay setting for threshold levels, over and under-currentoperationbullet CRD-005 Programmable dc voltage and mA set-point relay setting for threshold levels, over and under-voltage operationbullet CRD-005 internal DIP-switches allow for either 0-1mAdc or 0-10Vdc operation, and may be set for under-alarm or over-alarm relay operationbullet CRD-020 internal DIP-switch allow configuration of the ac current range to either 0-5A, 0-10A, 0-15A or 0-20A and the relay mode for under-current or over-current operationbullet Lid mounted two digit numerical push button switch calibrated as percent of full scale with a threshold range of 1-99%bullet Red LED lamp lights to indicate when the threshold level has been tripped

  • Signal Conditioning Instrumentation

    Columbia Research Laboratories

    Columbia offers a wide variety of Signal Conditioning Instrumentation for a variety of Sensor types. These range from Laboratory as well as Airborne Charge Amplifiers, Differential Charge Amplifiers, In-Line Charge Converters, Constant Current Power Supplies and ICP Compliant Amplifiers all in support of Columbia's extensive Piezoelectric product line. Additionally Columbia offers unique Strain Gage Instrumentation Amplifiers which provide built in auto zeroing of gage offset voltages which can increase typical measurement accuracies. These robust Signal Conditioning products have been flight qualified on many current military aircraft and missile programs and are now available for your distinctive program needs.

  • Electrical Safety Testers

    STW-9800 Series - Texio Technology Corp.

    * 200VA AC Test Capacity* 240 x 64 Ice Blue Dot Matrix LCD* Manual/Auto Mode* Function Key for Quick Selecting* High Intensity Flash for Caution & Status Indication* Safety Interlock Function* True RMS Current Measurement * High Resolution : 1μA for Measuring Current, 2V for Setting Voltage* PWM Switching Amplifier to Enhance the Power Efficiency and Reliable Testing* Max. 100 Memory Block for Test Condition (Step) Setting. And Each Step can be Named Individually* Remote Terminal on the Front Panel for“Start”and“Stop” Control by External* Interface: RS-232C, USB Devise, Signal I/O and GP-IB (Option: OPT.1)

  • PXI 6U Power Relay Module

    Pickering Interfaces Ltd.

    The SPDT Power Relay Module consists of 48 single pole changeover relays controlled by a PXI/CompactPCI interface. It is suitable for applications were conventional reed-relay based switching modules do not have sufficient voltage rating or current carrying capacity. All 48 contacts are electrically isolated from each other and are capable of switching resistive and inductive loads up to 2000VA at 240V AC. The module is built on a single width 6U PXI module and the interface is via a standard PXI/CompactPCI backplane. Connection to the switching contacts is via three 50-pin D-type male connectors mounted on the front panel. These are machined contact types with 7.5A current carrying capacity.

  • Insulation Meters

    PCE Instruments

    Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.

  • 1000A AC/DC True RMS Clamp/DMM + IR Thermometer

    Extech EX840 - Extech Instruments Corporation

    This CAT IV True RMS clamp meter features a built-in IR thermometer with laser pointer for non-contact surface measurements from -58 to 518 °F (-50 to 270 °C). Clamp measures AC current up to 1000 Amp with a maximum resolution of 0.1 Amp. The 1.7-inch jaw fits around conductors up to 750MCM. Peak hold captures motor inrush currents and other surges. Data hold and auto power off functions. Other functions include AC/DC Voltage, resistance, Type K thermometer, capacitance and frequency. Complete with test leads, Type K temperature probe, 9 Volt battery and case.

  • sbRIO-9218, Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module

    783362-02 - NI

    Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module - The sbRIO‑9218 helps you perform multipurpose testing. With the sbRIO‑9218, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors. You also can use the sbRIO‑9218 to perform quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. You can individually select and perform a different measurement type on each channel. Additionally, the sbRIO‑9218 features 60 VDC analog input isolation. Non-enclosed modules are designed for OEM applications.

  • Battery Capacity Tester

    BLU-A Series - IBEKO Power AB

    The battery capacity test is performed to determine the health of a battery. DV Power’s battery load unit BLU-A is a portable, powerful, and lightweight solution for battery capacity measurement. It is applicable to any battery string such as lead-acid, Li-Ion, Ni-Cd, etc., with up to 500 V battery voltage. As a special feature, BLU100L model enables the capacity testing of a single Li-Ion cell.The capacity test is performed in an accurate and user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.Battery load unit BLU-A enables setting discharge currents up to 240 A, with a resolution 0,1 A. Furthermore, if higher currents are required, BLU-A units can be connected in parallel, or additional BXL load units can be used.The instrument offers the best power-to-weight ratio in the market. BLU-A models start from 12,8 kg / 28.2 lbs and deliver up to 28,4 kW of power.The user can select three discharge modes:Constant current,Constant power,Constant resistance.Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.The instrument monitors discharge parameters in real-time during the capacity test. A 4,3-inch touch screen display shows battery voltage, current, elapsed time, and capacity during the entire test. Also, BLU battery load unit can be used with DV-B Win software. As a result of that, a user can see a detailed numerical and graphical presentation of key parameters and can create reports in various formats.Testing with BLU-A doesn’t require a disconnection of the battery from the testing equipment.

  • Voltmeter According to DIN EN 61010-1 (VDE 0411-1)

    PeakTech Prüf- und Messtechnik GmbH

    An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values ​​can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.

  • DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER

    TURNS-LCRTZ - Vasavi Electronics

    Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.

Get Help